Key Features
- 10 years warranty as standard – Can be extended to 20-year warranty
- Allows 1 to 8 Lithium Batteries
- Remote Upgrading – Firmware and parameter upgrading remotely
- Free monitoring – For Mobile & web portal (PC)
- Advanced Weather compensation programming
- Octopus Agile Tariff Ready
- Octopus Outgoing Tariff Ready
- Octopus Go Tariff Ready
- Grid Share Incentive ready
- Seamless automatic switch over – 0.01s
- Integrated EPS as standard – Maximum 13A Limited
- Smart export control on both AC & EPS output
- Max Charge & discharge rate of 70amps
- Lightweight – only 25Kg
- Quite operating noise levels – less then 25bB
- IP65 rated
- UK technical Support
LXP3600 Specification
- Battery Types Li-Ion or Lead-acid
- Nominal Battery Voltage (V) 48
- Max. Charging Voltage (V) SSO (Configurable)
- Max. Charging Current (A) 70
- Max. Discharging Current (A) 70
- Battery Capacity (kWh) >3
- Charging Mode for Li-Ion Battery Self-adaption to BMS
- Charging Mode for Lead-acid Battery 3-stage
Max.Apparent Power Output to Utility Grid (VA) 3600
Max.Apparent Power from Utility Grid (VA) 6000
Nominal Output Voltage (V) 230
Nominal Ouput Frequency (Hz) 50/60
Max.AC Current Output to Utility Grid (A} 16
Max.AC Current From Utilily Grid(A} 26
Output Power Factor -1 (Adjustable from 0.8 leading to 0.8 lagging)
Output THDI <3%
Grid Connection Single phase
Inrush Current 10A/10us
Max. Output Fault Current 50A/20us
- Max. Output Apparent Power (VA) 3600
- Peak Output Apparent Power (VA) 4700,30sec
- Automatic Switch Time <0.01s
- Nominal Output Voltage (V) 230 (±2%)
- Nominal Output Frequency (Hz} 50/60 (±0.2%)
- Max. Output Current (A) 16
- Back-up Over Current Protection(A} 40
- Output THDV (linear load} <3%
Anti-islanding Protection lntegrated(AFD)
Output Over Current Protection Integrated
Output Short Protection Integrated
Output Over Voltage Protection Integrated
Operation Temperature Range (‘C) -25-60
Storage Temperature (“C) -40-65
Relative Humidity 0-95%
Operation Altitude (m) 4000
Cooling Natural Convection
Noise (dB) <25
User Interface LCD &APP
Interface With BMS RS 485 /CAN
Communication With Cloud Wi-Fi
Weight (kg) 15.6
Size (Width•Height•Depth mm) 550•320·110
Mounting Wall Bracket
Protection Degree IP 65
Environment Category Outdoor & indoor
Standby Self Consumption (W) <10
Topology High Frequency Isolation
- Safety Regulation & EMC G83,CE, EN61000-6-1/3, EN62109-6-1/2, AS4777, IEC62040-1
Related Products
Specifications
- Battery Types Li-Ion or Lead-acid
- Nominal Battery Voltage (V) 48
- Max. Charging Voltage (V) SSO (Configurable)
- Max. Charging Current (A) 70
- Max. Discharging Current (A) 70
- Battery Capacity (kWh) >3
- Charging Mode for Li-Ion Battery Self-adaption to BMS
- Charging Mode for Lead-acid Battery 3-stage
- Max.Apparent Power Output to Utility Grid (VA) 3600
- Max.Apparent Power from Utility Grid (VA) 6000
- Nominal Output Voltage (V) 230
- Nominal Ouput Frequency (Hz) 50/60
- Max.AC Current Output to Utility Grid (A} 16
- Max.AC Current From Utilily Grid(A} 26
- Output Power Factor -1 (Adjustable from 0.8 leading to 0.8 lagging)
- Output THDI <3%
- Grid Connection Single phase
- Inrush Current 10A/10us
- Max. Output Fault Current 50A/20us
- Max. Output Apparent Power (VA) 3600
- Peak Output Apparent Power (VA) 4700,30sec
- Automatic Switch Time <0.01s
- Nominal Output Voltage (V) 230 (±2%)
- Nominal Output Frequency (Hz} 50/60 (±0.2%)
- Max. Output Current (A) 16
- Back-up Over Current Protection(A} 40
- Output THDV (linear load} <3%
- Anti-islanding Protection lntegrated(AFD)
- Output Over Current Protection Integrated
- Output Short Protection Integrated
- Output Over Voltage Protection Integrated
- Operation Temperature Range (‘C) -25-60
- Storage Temperature (“C) -40-65
- Relative Humidity 0-95%
- Operation Altitude (m) 4000
- Cooling Natural Convection
- Noise (dB) <25
- User Interface LCD &APP
- Interface With BMS RS 485 /CAN
- Communication With Cloud Wi-Fi
- Weight (kg) 15.6
- Size (Width•Height•Depth mm) 550•320·110
- Mounting Wall Bracket
- Protection Degree IP 65
- Environment Category Outdoor & indoor
- Standby Self Consumption (W) <10
- Topology High Frequency Isolation
- Safety Regulation & EMC G83,CE, EN61000-6-1/3, EN62109-6-1/2, AS4777, IEC62040-1