Harnitek Commercial Packages

""
""

With outputs of up to 90kW, the Harnitek Commercial Package is the class-leading Harnitek Power XR. With strong outputs, combined with flow temperatures of up to 60°C, it can be cascaded up to 16 units, making it ideal for larger buildings and systems.

The Power XR range has been designed to make the transition from traditional energy sources to a renewable alternative.

With an in-built control system which allows for easy integration with other thermal technologies and existing building management systems.

""

Harnitek Commercial at a Glance

Key Harnitek Commercial Features

""

Outputs of up to 90kW

Flow temperatures of up to 60c

Cascade up to 16 units

BMS-ready control unit

Simple installation

Highly efficient A++ ERP rated

Built-in weather compensation

Cost-effective solution

Smart defrosting

Two mixing circuits

WiFi module

Modbus communication

Emergency operation switch

Outputs of up to 90kW

Flow temperatures of up to 60c

Cascade up to 16 units

BMS-ready control unit

Simple installation

Highly efficient A++ ERP rated

Built-in weather compensation

Cost-effective solution

Smart defrosting

Two mixing circuits

WiFi module

Modbus communication

Emergency operation switch

Product Outline

Harnitek Commercial Package Specifications

Minimum/Maximum Heating Capacity: 7.9-25.1kW

El. Heating Power Input Minimum/Maximum: 2564-6172W

C.O.P Minimum/Maximum: 3.07-4.41

Minimum/Maximum Heating Capacity (2): 9.9-24.8kW

El. Heating Power Input Minimum/Maximum (2): 3141-7625W

C.O.P Minimum/Maximum (2): 3.16-3.43

Minimum/Maximum Heating Capacity (3): 10.6-21.5kW

El. Heating Power Input Minimum/Maximum (3): 2528-7678W

E.E.R Minimum/Maximum (3): 2.81-4.2W

Minimum/Maximum Cooling Capacity (4): 7.1-18.1kW

El. Cooling Power Input Minimum/Maximum (4): 2570-6746W

Minimum/Maximum Ambient Working Temperature in Heating Mode: -25-45°C

Minimum/Maximum Ambient Working Temperature in Cooling Mode: 20-45°C

Maximum Flow Temperature in Heating Mode: 60°C

Minimum Flow Temperature in Heating Mode: 10°C

Minimum Flow Temperature in Cooling Mode: 5°C

Sound Power Level: 62dB

Fan Quantity: 2pcs

Fan Airflow: 5000*2

Fan Rated Power: 118*2

Fan Blade Diameter: 550*2

Minimum/Maximum Heating Capacity: 15.2-28.7kW

El. Heating Power Input Minimum/Maximum: 3467-7488W

C.O.P Minimum/Maximum: 3.83-4.43

Minimum/Maximum Heating Capacity (2): 12.2-29.4kW

El. Heating Power Input Minimum/Maximum (2): 3769-9035W

C.O.P Minimum/Maximum (2): 3.26-3.43

Minimum/Maximum Heating Capacity (3): 15.2-26.8kW

El. Heating Power Input Minimum/Maximum (3): 3253-8765W

E.E.R Minimum/Maximum (3): 3.06-4.68W

Minimum/Maximum Cooling Capacity (4): 7.3-21.2kW

El. Cooling Power Input Minimum/Maximum (4): 3121-7960W

Minimum/Maximum Ambient Working Temperature in Heating Mode: -25-45°C

Minimum/Maximum Ambient Working Temperature in Cooling Mode: 20-45°C

Maximum Flow Temperature in Heating Mode: 60°C

Minimum Flow Temperature in Heating Mode: 10°C

Minimum Flow Temperature in Cooling Mode: 5°C

Sound Power Level: 62dB

Fan Quantity: 2pcs

Fan Airflow: 5250*2m3/h

Fan Rated Power: 93*2W

Fan Blade Diameter: 552*2mm

Minimum/Maximum Heating Capacity: 13.7-43.7kW

El. Heating Power Input Minimum/Maximum: 3325-12077W

C.O.P Minimum/Maximum: 3.62-4.42

Minimum/Maximum Heating Capacity (2): 13.6-43.2kW

El. Heating Power Input Minimum/Maximum (2): 4156-14308W

C.O.P Minimum/Maximum (2): 2.99-3.38W

Minimum/Maximum Heating Capacity (3): 17.7-32.0kW

El. Heating Power Input Minimum/Maximum (3): 3491-11771W

E.E.R Minimum/Maximum (3): 2.72-5.09W

Minimum/Maximum Cooling Capacity (4): 11.2-29.9kW

El. Cooling Power Input Minimum/Maximum (4): 3529-11640W

Minimum/Maximum Ambient Working Temperature in Heating Mode: -25-45°C

Minimum/Maximum Ambient Working Temperature in Cooling Mode: 20-45°C

Maximum Flow Temperature in Heating Mode: 55°C

Minimum Flow Temperature in Heating Mode: 10°C

Minimum Flow Temperature in Cooling Mode: 5°C

Sound Power Level: 66dB

Fan Quantity: 1pcs

Fan Airflow: 13500m3/h

Fan Rated Power: 800W

Fan Blade Diameter: 760mm

YHEPK-25V1MB Model Specification

Minimum/Maximum Heating Capacity: 7.9-25.1kW

El. Heating Power Input Minimum/Maximum: 2564-6172W

C.O.P Minimum/Maximum: 3.07-4.41

Minimum/Maximum Heating Capacity (2): 9.9-24.8kW

El. Heating Power Input Minimum/Maximum (2): 3141-7625W

C.O.P Minimum/Maximum (2): 3.16-3.43

Minimum/Maximum Heating Capacity (3): 10.6-21.5kW

El. Heating Power Input Minimum/Maximum (3): 2528-7678W

E.E.R Minimum/Maximum (3): 2.81-4.2W

Minimum/Maximum Cooling Capacity (4): 7.1-18.1kW

El. Cooling Power Input Minimum/Maximum (4): 2570-6746W

Minimum/Maximum Ambient Working Temperature in Heating Mode: -25-45°C

Minimum/Maximum Ambient Working Temperature in Cooling Mode: 20-45°C

Maximum Flow Temperature in Heating Mode: 60°C

Minimum Flow Temperature in Heating Mode: 10°C

Minimum Flow Temperature in Cooling Mode: 5°C

Sound Power Level: 62dB

Fan Quantity: 2pcs

Fan Airflow: 5000*2

Fan Rated Power: 118*2

Fan Blade Diameter: 550*2

YHEPK-30V1MB Model Specification

Minimum/Maximum Heating Capacity: 15.2-28.7kW

El. Heating Power Input Minimum/Maximum: 3467-7488W

C.O.P Minimum/Maximum: 3.83-4.43

Minimum/Maximum Heating Capacity (2): 12.2-29.4kW

El. Heating Power Input Minimum/Maximum (2): 3769-9035W

C.O.P Minimum/Maximum (2): 3.26-3.43

Minimum/Maximum Heating Capacity (3): 15.2-26.8kW

El. Heating Power Input Minimum/Maximum (3): 3253-8765W

E.E.R Minimum/Maximum (3): 3.06-4.68W

Minimum/Maximum Cooling Capacity (4): 7.3-21.2kW

El. Cooling Power Input Minimum/Maximum (4): 3121-7960W

Minimum/Maximum Ambient Working Temperature in Heating Mode: -25-45°C

Minimum/Maximum Ambient Working Temperature in Cooling Mode: 20-45°C

Maximum Flow Temperature in Heating Mode: 60°C

Minimum Flow Temperature in Heating Mode: 10°C

Minimum Flow Temperature in Cooling Mode: 5°C

Sound Power Level: 62dB

Fan Quantity: 2pcs

Fan Airflow: 5250*2m3/h

Fan Rated Power: 93*2W

Fan Blade Diameter: 552*2mm

YHEPK-45V1MB Model Specification

Minimum/Maximum Heating Capacity: 13.7-43.7kW

El. Heating Power Input Minimum/Maximum: 3325-12077W

C.O.P Minimum/Maximum: 3.62-4.42

Minimum/Maximum Heating Capacity (2): 13.6-43.2kW

El. Heating Power Input Minimum/Maximum (2): 4156-14308W

C.O.P Minimum/Maximum (2): 2.99-3.38W

Minimum/Maximum Heating Capacity (3): 17.7-32.0kW

El. Heating Power Input Minimum/Maximum (3): 3491-11771W

E.E.R Minimum/Maximum (3): 2.72-5.09W

Minimum/Maximum Cooling Capacity (4): 11.2-29.9kW

El. Cooling Power Input Minimum/Maximum (4): 3529-11640W

Minimum/Maximum Ambient Working Temperature in Heating Mode: -25-45°C

Minimum/Maximum Ambient Working Temperature in Cooling Mode: 20-45°C

Maximum Flow Temperature in Heating Mode: 55°C

Minimum Flow Temperature in Heating Mode: 10°C

Minimum Flow Temperature in Cooling Mode: 5°C

Sound Power Level: 66dB

Fan Quantity: 1pcs

Fan Airflow: 13500m3/h

Fan Rated Power: 800W

Fan Blade Diameter: 760mm

Harnitek Commercial in depth

Harnitek Commercial Package Overview

Hybrid Compatibility

The control panel is able to control up to 16 units as part of the Cascade system. This means that complex networks can be built out of the main unit, which can be easily controlled and maintained by the Harnitek Power XR Controller.

WiFi Module

With in-built Wi-Fi Module, the Power XR range can be remotely controlled and monitored. As soon as a service is required, the connectivity will allow diagnoses for quick and easy fixes.

Run In Rotation

No matter how many different individual units are connected to the system, every single unit can run alternately.

Having this feature means that you can efficiently service separate areas with heating as and when required.

Data Monitoring

In-built Performance Hub Gateway gives a real time view of system operation and performance anywhere in the world.

Additionally, the data is logged on an online monitoring platform, keeping an accurate record of performance and energy consumption throughout the year.

Exceptionally Efficient

The Power XR range has a highly efficient A++ ERP rating.

This makes the units a cost-effective solution, especially with the larger scale systems, ensuring that every bit of energy counts.

Testimonials

Quote icon

“We are delighted with our Luxpower system. We have recommended this system to our friends with confidence. We are absolutely confident that we have an excellent battery storage solution that it is performing exactly as we hoped it would”

John Smallwood, Leicester

Quote icon

“We just have a 12 panel system which we have had for 8 years. We have had a Luxpower battery storage system fitted and now we save all the daytime extra power which keeps us going in the evenings. The install was done by lunchtime, and we have the monitoring to check the system, although the screen on the unit is very clear.”

John d’Angibau, Colchester

Quote icon

“We are a large user of power but our house was not suitable for solar panels due to the large amount of trees around us. Our installer told us about the Luxpower Squirrel Pod system which means we can charge up with cheap electricity (we are on an Octopus account), and this keeps us going through the day. We have now has a second Luxpower unit fitted and 4 more batteries so we can fill them up at double the speed, and it now covers the oven when that comes on.”

Sam Hardacre, Sussex

View previous testimonial
View next testimonial

Our Blog

Latest Insights

How to Cut Down on Summer Energy Costs in 2024?

Top tips on how to save money and energy during the warmest months of the year.

Read More

How Big Can the Battery Grid Storage Market Get?

As renewable energy in the UK continues to grow and grow, forecasters and industry specialists alike have often pondered just how big can the battery grid storage market get.

Read More

What Should a Good Battery Storage Have?

Read on to find out the six key characteristics of what makes a good energy storage battery.

Read More

Battery Storage Packages by Infinity Innovations

At Infinity Innovations, we offer cutting-edge solar battery storage systems tailored to meet diverse and modern energy needs that the UK is currently facing. 

Read More

UK Heat Pump Grants Increased by 50%

The UK government recently announced a heat pump grant increase by 50%. Read to find out more.

Read More

Government Announces Tax Relief on Battery Storage Systems

In a move that is seen as an important step for energy efficiency, the UK government has announced tax reliefs on battery storage packs. Read to find out more.

Read More

What Would Happen If… The UK Switched to 100% Solar Energy?

What would the environmental benefits be if the UK switched entirely to solar power? What challenges and obstacles prevent more solar panels from being developed? Find this out and much more by reading on.

Read More

Inside Infinity: Battery Storage Packages

At Infinity Innovations, we offer cutting-edge solar battery storage systems tailored to meet diverse energy needs.

Read More

About Greenlinx

Greenlinx batteries are the only UK battery that has a 100% depth of discharge. This article explores more of the benefits.

Read More
Previous
Next
""